ELECTRIC
SYSTEM
FIAT PUNTO TRAINING OUTLINE
Fiat Auto S.p.A.
After Sales Training
node will exhibit the same behaviour as
the preceding step. Key-controlled
power supply (+15).
Cut-off with run-
down battery
Signal (CrashOutputSts) available
The function is ensured by an internal
power reserve for a maximum time of
150 msec.
In case of collision, the SDM will transmit, through the B-CAN line, a proper collision signal
(STATUS SDM.CrashOutputSts): this signal will inform the network about the type of collision
and the time when it occurred.
The airbag node will perform its functions, as shown in the table below:
Functions Driver’s
side
airbag
Passen
ger’s
side
airbag
Front
airbag
X
Internal
accelerom.
Y
Internal
accelerom.
X
Safety
function
Actuation
threshold
Front
protection
X
X
X
Pretensioner
Side
protection
X X
X
Side
limiter
Rear
protection
X
TBD
Fuel
cut-off
X
X
X
X
gb Fiat Grande Punto OK
507 / 532
© 2005 Fiat Auto S.p.A. – All rights reserved.