ELECTRIC
SYSTEM
FIAT PUNTO TRAINING OUTLINE
Fiat Auto S.p.A.
After Sales Training
Controls and operation (versions with 4 window regulators).
All the window regulators can be operated both manually and automatically, depending on the
logic described below.
Manual mode:
The window can be started and stopped manually by the user by pressing the control button
briefly (50 to 300 ms). When this button is released, the motor will stop.
the window is started manually by the user by pressing the control button for a long time
(longer than 300 ms). The window regulator will not be actuated when the control buttons are
pressed for less than 50 ms.
Automatic mode:
The window regulator operation will be interrupted when automatic operation is under way and
the window lifting or lowering control is pressed again.
The window regulating function can be actuated on all the windows only when the key is
inserted, except for window central closing/opening by means of the remote control and during
the timed period during which the key is not inserted, as described below.
Following the key-OFF, the front windows can only be actuated manually over a period of 3
minutes. After this time has elapsed, the system will not be acquiring new commands any
more.
In the event that, during the timing, door opening is detected, new commands will no longer be
acquired: only the commands (if any) received prior to the door opening will be completed.
If, upon key-OFF, any of the doors is open, the commands (if any) received prior to the door
opening will be completed.
The driver’s side window actuation is managed by the local controls.
The passenger’s side window actuation is managed both by the local and driver’s side control.
gb Fiat Grande Punto OK
474 / 532
© 2005 Fiat Auto S.p.A. – All rights reserved.
The rear window actuation is managed both by the local controls (one per window) and the
driver’s side controls.