4 . T S M S e r v i c e P r o g r a m
1 / 2 0 1 0
4 - 8
BA-TE-DE08C M.KAY
SW9xx_SM_Chapter 4-1-1_1-2010.doc/pdf <110301> yymmdd
B. Braun Avitum AG
Dialog
+
SW 9.xx
4.3
Structure of TSM Service Program
T S M S e r v i c e P r o g r a m
Technical Support and Maintenance (SW 9.xx)
Service
Reports
Operation Mode
Report
Treatment
Support
Dialysate Side Parameters
Heparin Parameters
Single Needle
Arterial Bolus Parameters
Min-Max Parameters
Disinfection Parameters
ABPM Parameters
bioLogic RR GL Parameters
Miscellaneous Parameters
DBI Parameters
DCI Parameters
Preventive Service
Rinsing Parameters
Timings
Summer Time Setting
Blood Side Parameters
UF Parameters
HDF/HF Online Parameters
Filter Parameters
Dialyser Filter Parameters Kt/V
Kt/V-UV Parameters
Langauge Selection
System
Configuration
Trends and
Trend Groups
Manual Test and
Calibration
Buttons, Lamps and Sounds
Touch Screen Calibration
Supervisor Window Test
Monitor Test
File System Check
ABPM Maintenance
DBI Test
Card Reader and Card Check
USB Port Properties
Kt/V-UV Sensor Test
DSI Test
TL Manual Test and
Calibration
Test 1.1 Staff Call/Alarms/Power Off
Test 1.3 Blood Pump Venous
Test 1.2 Blood Pump Arterial
Test 1.6 Pressure Sensors (Blood Side)
Test 1.9 Water Intake, Upline Tank and
Flow Pump FPE
Test 1.11 Dialysis Temperature
Test 1.4 Heparin Pump
Test 1.7 Safety Air Detector, Red Sensor
Test 1.10 Degassing and Heating
Test 1.5 Tubing Clamps
Test 1.8 Coupling Detectors
Test 1.12 Concentrate Pumps and
Conductivity
Test 1.14 By-Pass and Disinfection Valves
Test 1.19 Leak Test
Test 1.21 Emptying
Test 1.24 HDF Online
Test 1.25 HDF Online Valves and Coupling
Detectors
Test 1.26 Option Battery
Test 1.27 DFS Pressure Test of Therapy
Test 1.29 Patient Leakage Current
Test 1.28 Front Panel Board FPB (LLS)
Test 1.30 SMPS-MC Self Test
Test 1.31 Level Regulation
Test 1.15 Flow Pump FPA, Balance Chamber
and Air Separator
Sensors
Test 1.17 UF Pump
Test 1.16 Pressure Water Part
Test 1.20 Water Part (Overview)
{Test 1.22 HDF}
Test 1.23 BIC Cartridge Valves and
Coupling Detectors
Test 1.13 Balance Chamber Valves
Test 1.18 Blood Leak Detector
Low Level
Manual Test
Low Level Manual
Calibration
Calibration 2.1 Pressure Sensors (Blood Side)
Calibration 2.3 Pressure Sensors (Water Side)
Calibration 2.6 Conductivity
Calibration 2.9 Safety Air Detector SAD
{Calibration 2.11 Load Cell}
Calibration 2.4 Degassing Temperature
Calibration 2.7 Blood Leak Detector
Calibration 2.10 BICLF Ratio and ENDLF Ratio
Calibration 2.5 Dialysis Temperature
Calibration 2.8 Flow of BICP, KP and UF Pump
Calibration 2.12 PV Alarm Window, PA Low Limit
{Calibration 2.14 Substitution Pump}
Calibration 2.15 HDF Online Substitution Pump OSP
Calibration 2.16 Level Regulation Pump LRP
Calibration 2.13 Flow of BPA and BPV Pump
{Calibration 2.2 Heparin Pump}
Calibration 2.8.1 Stroke Value of BICP, KP and UFP
Calibration 2.8.2 Position Setting for BICP, KP and UFP
Calibration 2.13.1 Tube Constants of BPA and BPV
Calibration 2.13.2 Pump Head Selection
Brightness
Production
Report
Version Number
Dialog
Machine
Delivery Data
bioLogic RR
Card Reader
ABPM
Option Icons
DCI
Kt/V
Kt/V-UV (Crit-Line)
Low Level Options
Double Pump
DF Filter
HDF Online
Battery
Holder for BIC Cartridge
Nexadia-BSL (DBI)
WAN-BSL (DBI)
Save Calibration Data
Download Calibration Data
Hard Disk
Read/Write
File
Operations
HCT (Adimea)
Fig. : TSM Service Program
{} : not applicable