Rack-Mounting the SH1HU/FIBERMANAGEMENT and the FMT/1HU Shelf
206
Installation and Commissioning Manual
F
S
P
3000R
7 R
11
.1 8000
0015930
Issue
B
, ©
2012
ADVA AG Optical Netw
orking
ADVA Conf
idential
Tools and Parts Required
•
1 x ETSI bracket pair
•
Torx screwdriver TX20
The ETSI bracket pairs shown below are included in the shipping box.
Figure 56:
ETSI Adaptor Brackets for a FMT/1HU
To replace the 19-inch brackets with the ETSI brackets perform the following
steps:
Procedure
Step 1
Remove the 19-inch bracket on one side panel of the shelf as follows:
a) Using a Torx screwdriver TX20, turn the two screws fixing the
19-inch bracket in counter-clockwise direction until they are
removed from thread holes completely. Keep the removed
screws at hand.
b) Remove the bracket and put it aside.
Step 2
Fit the appropriate ETSI bracket to the shelf as follows:
Step 3
Place the appropriate bracket on the same side of the shelf in the cor-
rect position as illustrated in
The two threaded holes in the shelf side panel and the holes of the
bracket should line up.
Risk of damage due to electrostatic discharge!
To avoid possible ESD damages to sensitive circuit boards, do not
remove the shelf from anti-static packaging until you are ready to
commence fitting it with the appropriate brackets.
Observe standard precautions for handling shelves containing
ESD-sensitive devices.
CAUTION
Only Service Personnel are allowed to replace the brackets.