Chapter 10 Commissioning the Shelves
Installation and Commissioning Manual
353
F
S
P
3000R
7 R
11
.1 8000
0015930
Issue
B
, ©
2012
ADVA AG Optical Netw
orking
ADVA Conf
idential
Procedure
Step 1
Select System Management from the Craft Console main menu and
press ENTER.
- System Management
. System General Settings
. System OSPF Settings
. System IP Settings
. Logical Interfaces
. System Date & Time
. SNMP Configuration
. Software & Database Control
. Automatic Database Backup
. Alarm Profile
Step 2
Select System Date & Time from the System Management submenu
and press ENTER.
Step 3
Navigate to the squared-bracket Date (yyyy-mm-dd) field and press
ENTER to make it editable.
Step 4
Type the correct date using the syntax yyyy-mm-dd in the Date field
and press ENTER to exit the field.
Step 5
Navigate to the squared-bracket Time (hh:mm:ss on a 24 clock) field
and press ENTER to make it editable.
Step 6
Type the correct time using the syntax hh:mm:ss and 24 hour time in
the Time field and press ENTER to exit the field.
+-----------------------------System Date & Time------------------------------+
¦ ¦
¦ NTP Service Mode: [Server Only ] ¦
¦ ¦
¦ ¦
¦ Date (yyyy-mm-dd): [10-12-02 ] ¦
¦ Time (hh:mm:ss on a 24 clock): [11:21:34 ] ¦
¦ Time Zone: [[(Min:0,Max:20)AusACT] ¦
¦ Time Zone Offset: [36000 ] ¦
¦ Daylight Savings Time: [Y] ¦
¦ ¦
¦ ¦
¦ ¦
¦ IP Own IP Admin State Synchronization Stat ¦
¦ +-------------------------------------------------------------------------+ ¦
¦ ¦3.3.3.3 Default-IP IS NO_DATA ¦ ¦
¦ ¦172.26.2.22 Default-IP IS NO_DATA ¦ ¦
¦ ¦176.26.2.20 Default-IP IS NO_DATA ¦ ¦
¦ +-------------------------------------------------------------------------+ ¦