Installing the FSP 3000R7 ROADM-C40/40/OPM-3HU/2DC Shelf
216
Installation and Commissioning Manual
F
S
P
3000R
7 R
11
.1 8000
0015930
Issue
B
, ©
2012
ADVA AG Optical Netw
orking
ADVA Conf
idential
Mounting a ROADM-C40/40/OPM-3HU/2DC Shelf
into a Standard 23-Inch Rack
This subsection describes the procedure that must be followed in order to mount
the ROADM-C40/40/OPM-3HU/2DC Shelf into a standard 23-inch rack.
It is assumed that you are familiar with ESD-prevention precautions that should
be taken to avoid ESD damage to the equipment.
Tools and Parts Required
•
2 x 23 inch adapter brackets
•
4 x rack mounting screws for fixing the ROADM-C40/40/OPM-3HU/2DC
Shelf (delivered with the equipment). Use the screws provided or use
screws that fit the threaded holes in your rack.
•
Phillips head screwdriver
To mount the ROADM-C40/40/OPM-3HU/2DC into a 23 inch equipment rack,
perform the following steps:
Procedure
Step 1
Read the installation plan or the cabling plan to get information about:
•
the ROADM-C40/40/OPM-3HU/2DC
Shelf that is to be mounted
•
the rack, which is to hold this shelf
•
the position of this shelf within the rack
Step 2
On the rack mounting rails, locate and mark the mounting holes in
which the shelf has to be fixed. There should be no space between
the shelf below or above.
CAUTION
Only Service Personnel are allowed to mount
ROADM-C40/40/2-3HU-2DC shelves into a rack.
Risk of damage due to electrostatic discharge!
To avoid possible ESD damages to sensitive circuit boards, do not
remove the shelf from anti-static packaging until you are ready to
commence mounting.
Ensure that you are grounded with a wrist strap or equivalent while
mounting the brackets to a shelf which contains ESD-sensitive
devices
CAUTION
Lifting Hazard!
ROADM-C40/40/OPM-3HU/2DC Shelves are heavy. To avoid
personal injury and damage to a shelf, two persons should move, lift
and hold a shelf in position while a third person is securing it in the
rack.