Parameters 153
Defines the low limit for critical speed range 3.
Note:
This value must be less than or equal to the
value of parameter
.
0.00 rpm
-30000.00… 30000.00
rpm
Low limit for critical speed 3.
See par.
Defines the high limit for critical speed range 3.
Note:
This value must be greater than or equal to the
value of parameter
.
0.00 rpm
-30000.00… 30000.00
rpm
High limit for critical speed 3.
See par.
Determines when parameters
may change parameter
Selected
Not used
Motor potentiometer Up/Down sources (
and
) are disabled.
0
Used
Motor potentiometer Up/Down sources (
and
) are enabled.
1
While running
Motor potentiometer reference enable follows bit 4
(Following reference) of parameter
.
2
-
Activates and selects the mode of the motor
potentiometer.
See section
Speed control performance figures
in
Disabled
Motor potentiometer is disabled and its value set to
0.
0
Enabled (init at stop/
power-up)
When enabled, the motor potentiometer first adopts
the value defined by parameter
. The value can
then be adjusted from the up and down sources
defined by parameters
and
.
A power cycle will reset the motor potentiometer to
the predefined initial value (
1
Enabled (resume
always)
Enabled (init at stop/ power-up)
, but the motor
potentiometer value is retained over a power cycle.
2
Enabled (init to actual)
Whenever another reference source is selected, the
value of the motor potentiometer follows that
reference. After the source of reference returns to the
motor potentiometer, its value can again be changed
by the up and down sources (defined by
and
).
3
Enabled (resume/init
to Actual)
, but the motor
potentiometer ref act value is retained over power
cycle.
4
Defines an initial value (starting point) for the motor
potentiometer. See the selections of parameter
0.00
-32768.00… 32767.00
Initial value for motor potentiometer.
1 = 1
No.
Name/Value
Description
Default
FbEq 16
Summary of Contents for ACS280
Page 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Page 4: ......
Page 10: ...10 ...
Page 16: ...16 Control panel ...
Page 20: ...20 Start up ID run and use ...
Page 24: ...24 Default control connection ...
Page 88: ...88 Program features ...
Page 298: ...298 Parameters ...