68 Program features
Wiring example
The figure below shows a brake control wiring example. The brake control
hardware and wiring is to be sourced and installed by the customer.
WARNING!
Make sure that the machinery into which the drive with brake
control function is integrated fulfills the personnel safety regulations.
Note that the frequency converter (a Complete Drive Module or a Basic Drive
Module, as defined in IEC/EN 61800-2), is not considered as a safety device
mentioned in the European Machinery Directive and related harmonized
standards. Thus, the personnel safety of the complete machinery must not be
based on a specific frequency converter feature (such as the brake control
function), but it has to be implemented as defined in the application specific
regulations.
The brake is controlled by bit 0 of parameter
. In this
example, parameter
is set to
Brake command
(ie. bit 0 of
).
Motor
M
115/230 VAC
Mechanical brake
Brake control
hardware
Emergency
brake
5
NC
6
COM
7
NO
Drive control unit
Summary of Contents for ACS280