Parameters 133
Reference direction lock. Defines the direction of the
drive rather than the sign of the reference, except in
some cases.
In the table the actual drive rotation is shown as a
function of parameter
and Direction
command (from parameter
Request
In external control the direction is selected by a
direction command (parameter
or
If the reference comes from Constant (constant
speeds/frequencies), Motor potentiometer, PID, Fail,
Last (last speed reference), Jogging (jogging speed)
or Panel reference, the reference is used as is.
If the reference comes from a fieldbus:
• if the direction command is forward, the reference
is used as is
• if the direction command is reverse, the reference
is multiplied by -1.
0
Forward
Motor rotates forward regardless of the sign of the
external reference. (Negative reference values are
replaced by zero. Positive reference values are used as
is.)
1
Reverse
Motor rotates reverse regardless of the sign of the
external reference. (Negative reference values are
replaced by zero. Positive reference values are
multiplied by -1.)
2
No.
Name/Value
Description
Default
FbEq 16
Direction command =
Forward
Direction command =
Reverse
Direction command not
defined
=
Forward
Forward
Forward
=
Reverse
Reverse
Reverse
=
Forward, but
• If reference from
Constant, Motor
potentiometer, PID,
Safe speed, Last,
Jogging or Panel
reference, reference
used as is.
• If reference from the
network, reference
used as is.
Reverse, but
• If reference from
Constant, PID or Jogging
reference, reference used
as is.
• If reference from the
network, Panel, Analog
input, Motor
potentiometer, Safe
speed or Last reference,
reference multiplied by -1.
Forward
Summary of Contents for ACS280
Page 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Page 4: ......
Page 10: ...10 ...
Page 16: ...16 Control panel ...
Page 20: ...20 Start up ID run and use ...
Page 24: ...24 Default control connection ...
Page 88: ...88 Program features ...
Page 298: ...298 Parameters ...