Parameters 243
Supervision 4
Bit 3 of 32.01 Supervision status.
27
Supervision 5
Bit 4 of 32.01 Supervision status.
28
Supervision 6
Bit 5 of 32.01 Supervision status.
29
-
Selects the source of an external brake close request
signal. When on, the signal overrides the internal logic
and closes the brake.
0 = Normal operation/No external close signal
connected
1 = Close brake
Notes:
• In an open-loop (encoderless) application, if the
brake is kept closed by a brake close request
against a modulating drive for longer than 5
seconds, the brake is forced to close and the drive
trips on a fault, 71A5 Mechanical brake opening not
allowed.
• This parameter cannot be changed while the drive
is running.
Not used
Not used
0.
0
Used
1.
1
DI1
Digital input DI1 (10.02 DI delayed status, bit 0).
2
DI2
Digital input DI2 (10.02 DI delayed status, bit 1).
3
DI3
Digital input DI3 (10.02 DI delayed status, bit 2).
4
DI4
Digital input DI4 (10.02 DI delayed status, bit 3).
5
DIO1
Digital input/output DIO1 (11.02 DIO delayed status,
bit 0).
10
DIO2
Digital input/output DIO2 (11.02 DIO delayed status,
bit 1)
11
Not used
0.
0
Timed function 1
Bit 0 of 34.01 Timed functions status.
18
Timed function 2
Bit 1 of 34.01 Timed functions status.
19
Timed function 3
Bit 2 of 34.01 Timed functions status.
20
Supervision 1
Bit 0 of 32.01 Supervision status.
24
Supervision 2
Bit 1 of 32.01 Supervision status.
25
Supervision 3
Bit 2 of 32.01 Supervision status.
26
Supervision 4
Bit 3 of 32.01 Supervision status.
27
Supervision 5
Bit 4 of 32.01 Supervision status.
28
Supervision 6
Bit 5 of 32.01 Supervision status.
29
-
No.
Name/Value
Description
Default
FbEq 16
Summary of Contents for ACS280
Page 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Page 4: ......
Page 10: ...10 ...
Page 16: ...16 Control panel ...
Page 20: ...20 Start up ID run and use ...
Page 24: ...24 Default control connection ...
Page 88: ...88 Program features ...
Page 298: ...298 Parameters ...