250 Parameters
Defines a filter time for signal
100 ms
2…20000 ms
Motor torque signal filter time.
1 = 1 ms
Defines a filter time for signal
.
100 ms
2…20000 ms
Output power signal filter time.
1 = 1 ms
Defines the “at setpoint” limits for speed control of
the drive.
When the difference between reference (
) and the speed (
) is smaller than
,
the drive is considered to be “at setpoint”. This is
.
50.00 rpm
0.00…30000.00 rpm
Limit for “at setpoint” indication in speed control.
See par.
Defines the “at setpoint” limits for frequency control
of the drive. When the absolute difference between
reference (
Frequency ref ramp input
) and actual
frequency (
01.06
Output frequency
) is smaller than
46.22
At frequency hysteresis
, the drive is considered
to be “at setpoint”. This is indicated by bit 8 of
Main status word
.
2.00 Hz
0.00…1000.00 Hz
Limit for “at setpoint” indication in frequency control. See par.
No.
Name/Value
Description
Default
FbEq 16
0 rpm
(rpm)
(rpm)
-
(rpm)
Drive at setpoint
(
bit 8 = 1)
0 Hz
46.22
(Hz)
46.22
(Hz)
Drive at setpoint
(
bit 8 = 1)