378
Fieldbus control through the embedded fieldbus interface (EFB)
CANopen parameter settings for embedded fieldbus interface
Parameter
Setting for
fieldbus control
Function/Information
COMMUNICATION INITIALIZATION
Initializes embedded fieldbus
communication.
EMBEDDED MODBUS CONFIGURATION
3 (default)
Node address. There must be no
two nodes with the same node
address online.
125 kbps (default)
Defines the communication
speed of the link. Use the same
setting as in the master station.
(default)
Defines the action taken when a
communication loss is detected.
CAN objects
Bus: PDOs are configured by the
fieldbus master with SDO.
Drive parameters: PDO
configuration is determined by
drive parameters
,
and
.
CiA 402 (default)
Selects the control profile used by
the drive. See section Basics of
the user interface.
(default
),
(default for
Defines the types of fieldbus
references 1 and 2. The scaling
for each reference type is defined
by parameters
.
With the
setting, the type is selected
automatically according to the
currently active drive control
mode.
(default
),
(default for
,
Defines the types of actual values
1 and 2. The scaling for each
actual value type is defined by
parameters
. With
setting,
the type is selected automatically
according to the currently active
drive control mode.
Summary of Contents for ACS280
Page 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Page 4: ......
Page 10: ...10 ...
Page 16: ...16 Control panel ...
Page 20: ...20 Start up ID run and use ...
Page 24: ...24 Default control connection ...
Page 88: ...88 Program features ...
Page 298: ...298 Parameters ...