Parameters 185
-
Defines a minimum torque limit for the drive (in
percent of nominal motor torque). See diagram at
parameter
The limit is effective when
• the source selected by
is 0, or
•
is set to
.
WARNING!
Do not use minimum torque to stop
reverse rotation of the motor. Usage of
minimum torque limits disables the drive to
reach zero speed and fails to stop the motor.
-300.0%
-1600.0…0.0%
Minimum torque limit 1.
See par.
Defines a maximum torque limit for the drive (in
percent of nominal motor torque). See diagram at
parameter
The limit is effective when
• the source selected by
is 0, or
•
is set to
.
300.0%
0.0…1600.0%
Maximum torque 1.
See par.
Defines the source of the minimum torque limit for
the drive (in percent of nominal motor torque) when
• the source selected by parameter
is 1, or
•
is set to
.
See diagram at
.
Note:
Any positive values received from the selected
source are inverted.
Zero
None.
0
AI1 scaled
(see page
).
1
AI2 scaled
(see page
2
PID
(output of the
process PID controller).
15
Minimum torque 2
.
16
-
Defines the source of the maximum torque limit for
the drive (in percent of nominal motor torque) when
• the source selected by parameter
is 1, or
•
is set to
.
See diagram at
.
Note:
Any negative values received from the selected
source are inverted.
Zero
None.
0
AI1 scaled
(see page
).
1
AI2 scaled
(see page
2
PID
(output of the
process PID controller).
15
Maximum torque 2
.
16
No.
Name/Value
Description
Default
FbEq 16
Summary of Contents for ACS280
Page 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Page 4: ......
Page 10: ...10 ...
Page 16: ...16 Control panel ...
Page 20: ...20 Start up ID run and use ...
Page 24: ...24 Default control connection ...
Page 88: ...88 Program features ...
Page 298: ...298 Parameters ...