Parameters 247
Actual power that the motor absorbs when
connected direct-on-line and operating the
application. The value is used for reference when
energy savings are calculated.
Note:
The accuracy of the energy savings calculation
is directly dependent on the accuracy of this value. If
nothing is entered here, then the nominal motor
power is used by the calculation, but that may inflate
the energy savings reported as many motors do not
absorb nameplate power.
0.00 kW
0.00…100000.00 kW
Motor power.
1 = 1 kW
Resets the savings counter parameters
.
Done
Reset not requested (normal operation), or reset
complete.
0
Reset
Reset the savings counter parameters. The value
.
1
Value of the peak power during the last hour, that is,
the most recent 60 minutes after the drive has been
powered up.
The parameter is updated once every 10 minutes
unless the hourly peak is found in the most recent 10
minutes. In that case, the values is shown
immediately.
0.00 kW
-3000.00 … 3000.00
kW
Peak power value.
10 = 1 kW
Time of the peak power value during the last hour.
00:00:00
Time.
N/A
Total energy consumption during the last hour, that
is, the most recent 60 minutes.
You can reset the value by setting it to zero.
0.00 kWh
-3000.00 … 3000.00
kWh
Total energy.
10 = 1 kWh
Value of the peak power since midnight of the
present day.
You can reset the value by setting it to zero.
0.00 kW
-3000.00 … 3000.00
kW
Peak power value.
10 = 1 kW
Time of the peak power since midnight of the present
day.
00:00:00
Time.
N/A
Total energy consumption since midnight of the
present day.
You can reset the value by setting it to zero.
0.00 kWh
-30000.00 … 30000.00
kWh
Total energy.
1 = 1 kWh
Total energy consumption during the previous day,
that is, between midnight of the previous day and
midnight of the present day
0.00 kWh
No.
Name/Value
Description
Default
FbEq 16
Summary of Contents for ACS280
Page 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Page 4: ......
Page 10: ...10 ...
Page 16: ...16 Control panel ...
Page 20: ...20 Start up ID run and use ...
Page 24: ...24 Default control connection ...
Page 88: ...88 Program features ...
Page 298: ...298 Parameters ...