210 Parameters
Defines the hysteresis for the signal monitored by
signal supervision 6.
Note
: This parameter applies to all selections of
, not just Hysteresis.
0.00
0.00…100000.00
Hysteresis.
-
34
Motor thermal protection settings such as
temperature measurement configuration, load curve
definition and motor fan control configuration.
See also section
(page
).
Displays the motor temperature as estimated by the
internal motor thermal protection model (see
parameters
). The unit is selected by
.
This parameter is read-only.
-
-60…1000 °C
Estimated motor temperature.
1 = 1°
Displays the temperature received through the source
defined by parameter
.
The unit is selected by parameter
This parameter is read-only.
-
-60…5000 °C, or
-76…9032 °F, or
0...5000 ohm
Measured temperature 1.
Note:
With a PTC sensor, the unit is ohms.If the
measured temperature source selection (
analog I/O or PTC AI/DI Voltage divider tree, the
motor thermal protection function converts the
analog input signal (
) to PTC resistance value
(ohms), and shows it in this parameter. This is the
case even the parameter name and unit refer to
motor temperature (°C or °F). You cannot change the
unit to ohm for the time being (
).
1 = 1 unit
Shows the motor overload level as a percentage of
the motor overload fault limit.See section
0.0
0.0...300.0%
Motor overload level.
0.0% No motor overloading.
88.0% Motor overloaded to warning level.
100.0% Motor overloaded to fault level.
10 = 1%
Selects the source from which measured temperature
1 is read.
Usually this source is from a sensor connected to the
motor controlled by the drive, but it could be used to
measure and monitor a temperature from other parts
of the process as long as a suitable sensor is used as
per the selection list.
Disabled
None. Temperature monitoring function 1 is disabled. 0
Estimated temperature Estimated motor temperature (see parameter
The temperature is estimated from an internal drive
calculation. It is important to set up the ambient
temperature of the motor in
1
No.
Name/Value
Description
Default
FbEq 16
Summary of Contents for ACS280
Page 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Page 4: ......
Page 10: ...10 ...
Page 16: ...16 Control panel ...
Page 20: ...20 Start up ID run and use ...
Page 24: ...24 Default control connection ...
Page 88: ...88 Program features ...
Page 298: ...298 Parameters ...