242 Parameters
Defines a source that is used as a brake opening
torque reference if:
• its absolute value is greater than the setting of
parameter 44.10 Brake open torque, and
• its sign is the same as the setting of 44.10 Brake
open torque.
Brake open
torque
Zero
Zero.
0
AI1 scaled
12.12 AI1 scaled value.
1
AI2 scaled
12.22 AI2 scaled value.
2
FBA ref1
03.05 FB A reference 1.
3
FBA ref2
03.06 FB A reference 2.
4
Brake torque memory
Parameter 44.02 Brake torque memory.
7
Brake open torque
Parameter 44.10 Brake open torque.
8
Defines the sign (ie. direction of rotation) and
minimum absolute value of the brake open torque
(motor torque requested at brake release in percent
of motor nominal torque).
The value of the source selected by parameter 44.09
Brake open torque source is used as the brake open
torque only if it has the same sign as this parameter
and has a greater absolute value.
Note: This parameter is not effective in scalar motor
control mode.
0.0%
-1600.0 …1600.0%
Minimum torque at brake release.
See
par.
Selects a source that prevents the brake from
opening.
0 = Normal brake operation
1 = Keep brake closed
Note: This parameter cannot be changed while the
drive is running.
Not used
Not used
0.
0
Used
1.
1
DI1
Digital input DI1 (10.02 DI delayed status, bit 0).
2
DI2
Digital input DI2 (10.02 DI delayed status, bit 1).
3
DI3
Digital input DI3 (10.02 DI delayed status, bit 2).
4
DI4
Digital input DI4 (10.02 DI delayed status, bit 3).
5
DIO1
Digital input/output DIO1 (11.02 DIO delayed status,
bit 0).
10
DIO2
Digital input/output DIO2 (11.02 DIO delayed status,
bit 1)
11
Timed function 1
Bit 0 of 34.01 Timed functions status.
18
Timed function 2
Bit 1 of 34.01 Timed functions status.
19
Timed function 3
Bit 2 of 34.01 Timed functions status.
20
Supervision 1
Bit 0 of 32.01 Supervision status.
24
Supervision 2
Bit 1 of 32.01 Supervision status.
25
Supervision 3
Bit 2 of 32.01 Supervision status.
26
No.
Name/Value
Description
Default
FbEq 16
Summary of Contents for ACS280
Page 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Page 4: ......
Page 10: ...10 ...
Page 16: ...16 Control panel ...
Page 20: ...20 Start up ID run and use ...
Page 24: ...24 Default control connection ...
Page 88: ...88 Program features ...
Page 298: ...298 Parameters ...