84 Program features
use digital inputs to switch between user parameter sets. To change a user
parameter set, the drive has to be stopped.
A user parameter set contains all editable values in parameter groups 10…99
except Data storage parameters (
As the motor settings are included in the user parameter sets, make sure the
settings correspond to the motor used in the application before recalling a user
set. In an application where different motors are used with the drive, the motor
ID run needs to be performed with each motor and the results saved to
different user sets. The appropriate set can then be recalled when the motor is
switched.
Settings and diagnostics
Parameters
.
Events: -
Data storage parameters
Twelve (eight 32-bit, four 16-bit) parameters are reserved for data storage.
These parameters are unconnected by default and can be used for linking,
testing and commissioning purposes. They can be written to and read from
using other parameters’ source or target selections.
Settings and diagnostics
Parameter group
(page
Events: -
Parameter checksum calculation
Parameter checksums A and B can be calculated from a set of parameters to
monitor changes in the drive configuration. The parameter sets are different for
A and B. Each of the calculated checksum is compared to corresponding
reference checksum. If a mismatch occurs, the drive generates an event (a pure
event, warning or fault). The calculated checksum can be set as the new
reference checksum.
The set of parameters for checksum A does not include fieldbus settings
parameters.
The parameters included in the checksum A calculation are user editable
parameters in parameter groups 10, 15, 19, 20, 21, 22, 23, 24, 25, 28, 30, 31, 32, 35,
36, 37, 40, 45, 46, 95, 96, 97, 98, and 99.
Summary of Contents for ACS280
Page 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Page 4: ......
Page 10: ...10 ...
Page 16: ...16 Control panel ...
Page 20: ...20 Start up ID run and use ...
Page 24: ...24 Default control connection ...
Page 88: ...88 Program features ...
Page 298: ...298 Parameters ...