102 Parameters
06
Drive control and status words.
The main control word of the drive. This parameter
shows the control signals as received from the
selected sources (such as digital inputs, the fieldbus
interfaces and the application program).
The bit assignments of the word are as described on
. The related status word are presented on
pages
.
This parameter is read-only.
Note:
With the fieldbus control, the parameter value
is not same as the value that it receives from the PLC.
0000h
0000h…FFFFh
Main control word.
1 = 1
No.
Name/Value
Description
Default
FbEq 16
Bit
Name
0
Off1 control
1
Off2 control
2
Off3 control
3
Run
4
Ramp out zero
5
Ramp hold
6
Ramp in zero
7
Reset
8
Inching 1
9
Inching 2
10
Remote cmd
11
Ext ctrl loc
12
User bit 0
13
User bit 1
14
User bit 2
15
User bit 3