278 Parameters
Displays the actual parameter configuration
checksum B. The checksum B is generated and
updated whenever an action is selected in
bit 9 = 1 (Approved checksum B)
The set of parameters for checksum B does not
include:
• fieldbus settings
• motor data settings, and
• energy data settings parameters.
The parameters included in the checksum B
calculation are user editable parameters in parameter
groups 10, 15, 19, 20, 21, 22, 23, 24, 25, 28, 30, 31, 32, 35,
36, 37, 40, 41, 46, 71, 95, 96, and 97.
See also section
Parameter checksum calculation
(page
).
0x0000
0x0000...0xffff
Actual checksum B.
1 = 1
Selects if the adaptive program is enabled or disabled
No
Adaptive program is enabled. Adaptive program is set
to running mode automatically when drive is powered
on. Commanding adaptive program to running mode
is possible from PC tool.
0
Yes
Adaptive program is disabled. Setting adaptive
program to running mode is not possible. If adaptive
program was running when disabled, then adaptive
program is stopped and set to init state.
1
Approved (reference) checksum A.
0x0000
0x0000...0xffff
Approved checksum A.
-
Approved (reference) checksum B.
0x0000
0x0000...0xffff
Approved checksum B.
-
(Visible when user lock is open)
To change the current user pass code, enter a new
code into this parameter as well as
. A warning
will be active until the
new pass code is confirmed. To cancel changing the
pass code, close the user lock without confirming. To
close the lock, enter an invalid pass code in parameter
, activate parameter
, or cycle the power.
See also section
(page
).
10000000
10000000…
99999999
New user pass code.
-
(Visible when user lock is open)
Confirms the new user pass code entered in
10000000…
99999999
Confirmation of new user pass code.
-
No.
Name/Value
Description
Default
FbEq 16
Summary of Contents for ACS280
Page 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Page 4: ......
Page 10: ...10 ...
Page 16: ...16 Control panel ...
Page 20: ...20 Start up ID run and use ...
Page 24: ...24 Default control connection ...
Page 88: ...88 Program features ...
Page 298: ...298 Parameters ...