Parameters 251
Defines the “at setpoint” limits for torque control of
the drive. When the absolute difference between
reference (
) and actual
torque (
, the drive is considered to be “at
setpoint”. This is indicated by bit 8 of
5.0%
0.0…300.0%
Limit for “at setpoint” indication in torque control.
See par.
Defines the trigger level for “above limit” indication in
speed control. This is indicated by bit 10 of parameter
and parameter
. When actual speed
exceeds the limit, bit 10 of
is
set.
1500.00 rpm
0.00…30000.00 rpm
“Above limit” indication trigger level for speed
control.
See par.
Defines the trigger level for “above limit” indication in
frequency control. This is indicated by bit 10 of
parameter
and parameter
. When actual
frequency exceeds the limit, bit 10 of
is set.
50.00 Hz
0.00…1000.00 Hz
“Above limit” indication trigger level for frequency
control.
See par.
Defines the trigger level for “above limit” indication in
torque control. This is indicated by bit 10 of
parameter
and parameter
. When actual
torque exceeds the limit, bit 10 of
is set.
300.0%
0.0…1600.0%
“Above limit” indication trigger level for torque
control.
See par.
Defines the trigger level for the “kWh pulse” on for 50
ms. The output of the pulse is bit 9 of
1.000 kWh
0.001… 1000.000 kWh
“kWh pulse” on trigger level.
1 = 1 kWh
Defines the number of display decimals places and
32-bit scaling of power-related parameters. The value
of this parameter corresponds to the number of
decimals assumed in the 32-bit integer fieldbus
communication (for 16-bit scaling see
).
2
0…3
Number of decimals.
1 = 1
No.
Name/Value
Description
Default
FbEq 16
(%)
0%
(%)
Drive at setpoint
(
bit 8 = 1)
Summary of Contents for ACS280
Page 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Page 4: ......
Page 10: ...10 ...
Page 16: ...16 Control panel ...
Page 20: ...20 Start up ID run and use ...
Page 24: ...24 Default control connection ...
Page 88: ...88 Program features ...
Page 298: ...298 Parameters ...