158 Parameters
Defines the shape of the acceleration and
deceleration ramps used with the set 1.
0.000 s: Linear ramp. Suitable for steady acceleration
or deceleration and for slow ramps.
0.001…1000.000 s: S-curve ramp. S-curve ramps are
ideal for lifting applications. The S-curve consists of
symmetrical curves at both ends of the ramp and a
linear part in between.
Acceleration:
Deceleration:
0.000 s
0.100…1800.000 s
Ramp shape at start and end of acceleration and
deceleration.
10 = 1 s
Defines the shape of the acceleration and
deceleration ramps used with the set 2. See
.
0.000 s
0.100…1800.000 s
Ramp shape at start and end of acceleration and
deceleration.
10 = 1 s
No.
Name/Value
Description
Default
FbEq 16
S-curve ramp:
> 0 s
Linear ramp:
= 0 s
Linear ramp:
= 0 s
S-curve ramp:
> 0 s
Speed
Time
S-curve ramp:
> 0 s
Linear ramp:
S-curve ramp:
Speed
Time
Linear ramp:
= 0 s