128 Parameters
In1P Start fwd; In2P
Start rev; In3 Stop
The sources of the start and stop commands are
selected by parameter
.The
source selected by parameters
and
determines the direction.
The state transitions of the source bits are
interpreted as follows:
Note:
Parameter
effect with this setting.
6
Control panel
Start; stop and direction commands through control
panel; when EXT1 is active. Applies also for PC-Tool
when it is connected via panel port.
11
Embedded fieldbus
The start and stop commands are taken from the
embedded fieldbus interface.
Note:
The start signal is always level-triggered with
this setting regardless of parameter
14
Defines whether the start signal for external control
location EXT1 is edge-triggered or level-triggered.
Note:
This parameter is not effective if a pulse-type
start signal is selected. See the descriptions of the
selections of parameter
.
Edge
The start signal is edge-triggered.
0
Level
The start signal is level-triggered.
1
Selects source 1 for parameter
Always off
0 (always off).
0
Always on
1 (always on).
1
DI1
Digital input DI1 (
2
DI2
Digital input DI2 (
, bit 1).
3
DI3
Digital input DI3 (
, bit 2).
4
DI4
Digital input DI4 (
, bit 3).
5
Supervision 1
.
24
Supervision 2
Bit 1 of
.
25
Supervision 3
.
26
Supervision 4
.
27
Supervision 5
28
Supervision 6
Bit 5 of
29
Source selection (see
).
-
Selects source 2 for parameter
.
For the available selections, see parameter
.
No.
Name/Value
Description
Default
FbEq 16
State of
source 1
(
)
State of
source 2
(
)
State of
source 3
Command
0 -> 1
Any
1
Start forward
Any
0 -> 1
1
Start reverse
Any
Any
0
Stop
Summary of Contents for ACS280
Page 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Page 4: ......
Page 10: ...10 ...
Page 16: ...16 Control panel ...
Page 20: ...20 Start up ID run and use ...
Page 24: ...24 Default control connection ...
Page 88: ...88 Program features ...
Page 298: ...298 Parameters ...