Parameters 113
Contains the value of digit output that is used instead
of the connected signals if selected in parameter
. Bit 0 is the forced value for DO1.
This provides the possibility to test the drive
functionality
without the plant wiring. T
on
and T
off
delays are
passed.
0000h
0000h...FFFFh
Forced values of digital outputs.
1=1
Selects whether DIO1 is used as a digital output, or
analog output.
Analog
output
Selects a drive signal to be connected to digital
output DO1.
Not energized
Output is not energized.
0
Energized
Output is energized.
1
Ready run
Enabled
.
4
Started
Bit 5 of
5
Magnetized
.
6
Running
Bit 6 of
.
7
Ready ref
.
8
At setpoint
Bit 8 of
.
9
Reverse
.
10
Zero speed
.
11
Above limit
Bit 10 of
12
Warning
.
13
Fault
14
Fault (-1)
15
Fault/Warning
A warning or fault is active.
16
Overcurrent
A drive is tripped to overcurrent fault.
17
Overvoltage
A drive is tripped to overvoltage fault.
18
Drive temp
A drive is tripped to drive temperature fault.
19
Undervoltage
A drive is tripped to undervoltage fault.
20
Motor temp
A drive is tripped to motor temperature fault.
21
No.
Name/Value
Description
Default
FbEq 16
Bit
Value
0
Force the value of this bit to DO1, if so defined in parameter
1...15
Reserved
Index
Name
Description
10
Digital output
DIO pin used as digital output.
13
Analog output
DIO pin used as Analog output.
Summary of Contents for ACS280
Page 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Page 4: ......
Page 10: ...10 ...
Page 16: ...16 Control panel ...
Page 20: ...20 Start up ID run and use ...
Page 24: ...24 Default control connection ...
Page 88: ...88 Program features ...
Page 298: ...298 Parameters ...