Fieldbus control through the embedded fieldbus interface (EFB)
605D
h
0
Halt option
code
INT16 RW
This object indicates what action is
performed when the halt function is
executed, i.e. when the halt bit in the
Control word is set.
The slow down ramp is the deceleration
value of the used mode of operations.
The following value definition is valid:
1 = slow down on slow down ramp and
stay in OPERATION ENABLED
2 = slow down on quick stop ramp and
stay in OPERATION ENABLED
3 = slow down on the current limit and
stay in OPERATION ENABLED
4 = slow down on voltage limit and
stay in OPERATION ENABLED
6060h 0
Mode of
Operation
INT8
RW
The operational mode is selectable by
this object. This object shows only the
value of the requested operation mode,
the actual operation mode of the PDS is
reflected in the object 6061h.
The following value definition is valid:
0 = no mode change / no mode
assigned
1 = profile position mode (not
supported)
2 = velocity mode
3 = profile velocity mode
4 = profile torque mode
5 = reserved
6 = homing mode (not supported)
7 = interpolated position mode (not
supported)
8 = cyclic synchronous position mode
(not supported)
9 = cyclic synchronous velocity mode
10 = cyclic synchronous torque mode
Index
Sub-
inde
x
Name
Type
Access Description
Summary of Contents for ACS280
Page 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Page 4: ......
Page 10: ...10 ...
Page 16: ...16 Control panel ...
Page 20: ...20 Start up ID run and use ...
Page 24: ...24 Default control connection ...
Page 88: ...88 Program features ...
Page 298: ...298 Parameters ...