Parameters 107
-
Selects a binary source whose status is transmitted
.
False
0.
0
True
1.
1
-
Selects a binary source whose status is transmitted
as bit 14 (User bit 3) of
.
False
0.
0
True
1.
1
-
07
Drive hardware and firmware information.
All parameters in this group are read-only.
Type of the drive/inverter unit.
-
Firmware identification.
-
Version number of the firmware.
-
Name of the firmware loading package.
-
Version number of the firmware loading package.
-
Microprocessor load in percent.
-
0…100%
Microprocessor load.
1 = 1
First five ASCII letters of the name given to the
customization package. The full name is visible under
System info on the control panel or the Drive
composer PC tool.
_N/A_ = None.
-
Customization package version number. Also visible
under System info on the control panel or the Drive
composer PC tool.
-
Shows the status of the adaptive program.
See section
on page
.
-
0000h…FFFFh
Adaptive program status
1 = 1
Shows the number of the active state of the sequence
program part of the adaptive program (AP). If
adaptive programming is not running, or it does not
contain a sequence program, the parameter is zero.
No.
Name/Value
Description
Default
FbEq 16
Bit
Name
Description
0
Initialized
Adaptive program initialized.
1
Editing
Adaptive program in editing state.
2
Edit done
Editing of the adaptive program finished.
3
Running
Adaptive program running.
4-13
Reserved
14
State
changing
State changing on-going in the adaptive programming engine.
15
Faulted
Adaptive program faulted.
Summary of Contents for ACS280
Page 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Page 4: ......
Page 10: ...10 ...
Page 16: ...16 Control panel ...
Page 20: ...20 Start up ID run and use ...
Page 24: ...24 Default control connection ...
Page 88: ...88 Program features ...
Page 298: ...298 Parameters ...