Parameters 181
Displays the torque controller limitation status word.
This parameter is read-only.
-
0000h…FFFFh
Torque limitation status word.
1 = 1
No.
Name/Value
Description
Default
FbEq 16
Bit
Name
Description
0
Undervoltage
*1 = Intermediate DC circuit undervoltage
1
Overvoltage
*1 = Intermediate DC circuit overvoltage
2
Minimum torque *1 = Torque is being limited by
or
3
Maximum torque *1 = Torque is being limited by
or
4
Internal current
1 = An inverter current limit (identified by bits 8…11) is active
5
Load angle
(With permanent magnet motors and reluctance motors only)
1 = Load angle limit is active, ie. the motor cannot produce any
more torque
6
Motor pullout
(With asynchronous motors only)
1 = Motor pull-out limit is active, ie. the motor cannot produce any
more torque
7
Reserved
8
Thermal
1 = Input current is being limited by the main circuit thermal limit
9
Max current
*1 = Maximum output current (
I
MAX
) is being limited
10
User current
*1 = Output current is being limited by
11
Thermal IGBT
*1 = Output current is being limited by a calculated thermal
current value
12
IGBT
overtemperature
*1 = Output current is being limited because of the estimated
IGBT temperature
13
IGBT overload
*1 = Output current is being limited because of the IGBT junction
to case temperature
14…15 Reserved
*Only one out of bits 0…3, and one out of bits 9…11 can be on simultaneously. The bit
typically indicates the limit that is exceeded first.
Summary of Contents for ACS280
Page 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Page 4: ......
Page 10: ...10 ...
Page 16: ...16 Control panel ...
Page 20: ...20 Start up ID run and use ...
Page 24: ...24 Default control connection ...
Page 88: ...88 Program features ...
Page 298: ...298 Parameters ...