Parameters 129
Selects source 3 for parameter
.
For the available selections, see parameter
Selects the source of start, stop and direction
commands for external control location 2 (EXT2).
See also parameters
…
. See parameter
for the determination of the actual direction.
not used
No start or stop command sources selected.
0
In1 Start
The source of the start and stop commands is
selected by parameter
. The
state transitions of the source bits are interpreted as
follows:
1
In1 Start; In2 Dir
is the
start signal; the source selected by
determines the direction. The state
transitions of the source bits are interpreted as
follows:
2
In1 Start fwd; In2 Start
rev
is the
forward start signal; the source selected by
is the reverse start signal. The state
transitions of the source bits are interpreted as
follows:
3
No.
Name/Value
Description
Default
FbEq 16
State of source 1
)
Command
0 -> 1 (
1 (
=
Start
0
Stop
State of source 1
State of source 2
Command
0
Any
Stop
0 -> 1 (
=
)
)
0
Start
forward
1
Start
reverse
State of source 1
(
)
State of source 2
Command
0
0
Stop
0 -> 1 (
=
0
Start
forward
0
0 -> 1 (
=
Start
reverse
1
1
Stop