43
External I/O Circuits
Section 3-3
CN1 Control Input Signal Connection Diagram
Note
(1) If the limit input signal inputs (Servo Drive's forward drive prohibited sig-
nal and reverse drive prohibited signal) are not allocated, the Servo Drive
will not stop the Servomotor when the signal is input, and the Position
Control Unit will also not detect limit inputs as errors. When using a Posi-
tion Control Unit, always allocate the Servo Drive's forward drive prohib-
ited signal and reverse drive prohibited signal to enable use of the limit
input signals. (Refer to
6-4 Standard Settings for Servo Drives Using
MECHATROLINK
.)
(2) The signal width of the limit input signals (forward drive prohibited signal
and reverse drive prohibited signal) and origin proximity input signal (ori-
gin return deceleration limit switch) must be longer than the MECHA-
TROLINK communications cycle. If the input signal width is shorter than
the communications cycle, the Position Control Unit will be unable to de-
tect the input signal.
(3) When selecting a sensor for the origin proximity input signal (origin return
deceleration LS), use a sensor such as a Photoelectric Sensor, which
does not have chattering, because the origin signal is detected after the
input goes from ON to OFF during the origin search. If a switch with con-
tacts is used, the origin position may shift due to the switch contact's chat-
tering.
CN1 Control Output
Signals
1
+24VIN
4.7 k
Ω
External power supply:
12 VDC
±
5% to
24 VDC
±
5%
Power supply capacity:
50 mA min. (per Unit)
To other input circuit
ground commons
To other input circuits
Photocoupler input
Signal Levels
ON level: 10 V min.
OFF level: 3 V max.
Pin No.
Symbol
Name
Function/Interface
15
/ALM
Alarm Output
The output is OFF when an
alarm is generated in the Servo
Drive.
16
ALMCOM
29
OUTM2
General-purpose Out-
put 2 (READY)
This is a general-purpose out-
put. The function for this output
is selected by changing the
parameter.
Refer to Output Signal Assign-
ment Details on the next page.
30
OUTM2COM
31
OUTM3
General-purpose Out-
put 3 (CLIM)
32
OUTM3COM
36
OUTM1
General-purpose Out-
put 1 (BKIR)
35
OUTM1COM
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...