![Omron CJ1W-MA - REV 10-2008 Скачать руководство пользователя страница 162](http://html1.mh-extra.com/html/omron/cj1w-ma-rev-10-2008/cj1w-ma-rev-10-2008_operation-manual_742343162.webp)
135
Servo Parameter Area
Section 4-5
Param-
eter No.
Parame-
ter name
Param-
eter
size
Contents
Default
setting
Unit
Setting range
Enable
setting
Details
Digit
No.
Name
Set-
ting
Explanation
Pn816
Zero
point
return
mode set-
ting
2
0
Zero point
return direc-
tion
0
Forward
0
---
---
Online
Set the
same direc-
tion as the
origin
search
direction set
in the Axis
Parameters.
Settings can
be changed
when the
axes are
stopped
(Busy Flag
for each
axis = 0).
1
Reverse
1 to 3
Not used.
0
(Do not
change the
setting.)
0
---
---
---
---
Pn817
Zero
point
return
approach
speed 1
2
Sets the origin (zero point) input signal
search speed used after the origin proximity
signal has been detected in an origin search.
50
×100
com-
mand
units/s
0 to 65535
Online
Settings can
be changed
when the
axes are
stopped
(Busy Flag
for each
axis = 0).
Pn818
Zero
point
return
approach
speed 2
2
Sets the origin (zero point) return final travel
distance positioning speed used after the ori-
gin input signal has been detected in an ori-
gin search.
5
×100
com-
mand
units/s
0 to 65535
Online
Settings can
be changed
when the
axes are
stopped
(Busy Flag
for each
axis = 0).
Pn819
Final
travel dis-
tance to
return to
zero point
4
Sets the amount of compensation positioning
used after the origin input signal has been
detected in an origin search.
100
Com-
mand
unit
−
1,073,741,823
to
1,073,741,823
Online
Settings can
be changed
when the
axes are
stopped
(Busy Flag
for each
axis = 0).
Pn81B
Backlash
compen-
sation
amount
2
Sets the amount of backlash compensation.
0
×
0.1
com-
mand
unit
−
32,768 to
32,767
Online
---
Pn81C
Not used.
---
(Do not change the setting.)
0000
---
---
---
---
Pn81D
Compen-
sation
function
selection
2
0
Backlash
compensa-
tion selec-
tion
0
Compen-
sates in for-
ward
direction.
0
---
---
Offline
---
1
Compen-
sates in
reverse
direction.
1 to 3
Not used.
0
(Do not
change the
setting.)
0
---
---
---
---
Pn81E
to
Pn823
Not used.
---
(Do not change the setting.)
0000
---
---
---
---
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...
Страница 643: ...616 Revision History ...