280
Origin Search Operation
Section 8-2
Servo Parameters
G-series Limit Input Operation Parameters
W-series Limit Input Operation Parameters
Note
The Pn406 default setting corresponds to that used for W-series Servo Drives.
The stop operation (Pn066 for G Series and Pn001.1 for W Series) sets the
stop operation of the Servomotor for forward/reverse rotation limit inputs when
prohibited drive is input.
When reversal mode is used for the origin search, it is also used as the opera-
tion setting when limit inputs are input in the origin search direction. The
parameter size for Pn001.1 for W-series Servo Drives is the value to be spec-
ified when transferring the Servo Parameter Pn001 (including Pn001.1).
The emergency stop torque (Pn06E for G Series and Pn406 for W Series)
sets the stopping torque when the stop operation for limit inputs is set to 1
(decelerates to a stop at set torque or lower, and locks Servo in zero clamp
mode), or 2 (decelerates to a stop at set torque or lower, and puts Servo in
free run state).
When using a SMARTSTEP Junior Servo Drive, the Servomotor will deceler-
ate to a stop with the maximum Servomotor torque and the Servo will be
locked when the forward or reverse rotation limit input is received.
Parameters for Using G-series Absolute Encoders
Parameters for Using W-series Absolute Encoders
When using a Servomotor with absolute encoder, select whether the absolute
encoder will be used as an absolute encoder or as an incremental encoder.
These parameter settings are disabled if a Servomotor with incremental
encoder is used.
Set this parameter to 1 or 2 for a G-series Servo Drive, and 1 for a W-series
Servo Drive, if using a Servomotor with absolute encoder as a Servomotor
with incremental encoder.
Type Parame-
ter No.
Parameter name
Unit
Setting
range
Parame-
ter size
Default
setting
---
Pn066
Stop selection for drive prohibition input ---
0 to 2
2
0
---
Pn06E
Emergency stop torque
%
0 to 500
2
0
Type Parame-
ter No.
Parameter name
Unit
Setting
range
Parame-
ter size
Default
setting
W Series
SMART-
STEP
Junior
---
Pn001.1
Function selection application switch 1
Select stop when prohibited drive is
input
---
0 to 2
2
0
Sup-
ported
Not sup-
ported
---
Pn406
Emergency stop torque
%
0 to 800
2
350
Sup-
ported
Not sup-
ported
Type Parame-
ter No.
Parameter name
Unit
Setting
range
Parame-
ter size
Default
setting
---
Pn00B
Operation switch when using absolute
encoder
---
0 to 2
2
0
Type Parame-
ter No.
Parameter name
Unit
Setting
range
Parame-
ter size
Default
setting
W Series
SMART-
STEP
Junior
---
Pn002.2
Function selection application switch 2
Operation switch when using abso-
lute encoder
---
0, 1
2
0
Sup-
ported
Not sup-
ported
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...
Страница 643: ...616 Revision History ...