![Omron CJ1W-MA - REV 10-2008 Скачать руководство пользователя страница 398](http://html1.mh-extra.com/html/omron/cj1w-ma-rev-10-2008/cj1w-ma-rev-10-2008_operation-manual_742343398.webp)
371
Speed Control
Section 10-5
The settings for option command values 1 and 2 (torque limit/torque feed for-
ward command values) and Forward/Reverse Rotation Current Limit Designa-
tion Bits are enabled when the SPEED CONTROL Bit turns ON. Changing
these command values while speed control is being executed and then turn-
ing ON the SPEED CONTROL Bit again enables the option command values
and Current Limit Designation Bits to be changed during operation.
The torque limit for speed control set in the option command values can be
used together with the torque limit function (refer to
10-4 Torque Limits
). When
enabling multiple torque limit functions simultaneously, the Servomotor's out-
put torque is limited by the minimum torque limit setting.
3
0
0
Option command values 1 and
2 are disabled. Use set value 0.
Option command values 1 and
2 are disabled. Use set value 0.
0
1
Option command value 2
(words a+12, a+13) functions
as a reverse torque limit value
and the torque limit function is
enabled.
Option command value 2
(words a+12, a+13) functions
as a reverse torque limit value
and the torque limit function is
enabled.
1
0
Option command value 1
(words a+10, a+11) functions
as a forward torque limit value
and the torque limit function is
enabled.
Option command value 1
(words a+10, a+11) functions
as a forward torque limit value
and the torque limit function is
enabled.
1
1
Option command value 1
(words a+10, a+11) functions
as a torque limit value and the
torque limit function is enabled
in both directions.
Option command value 1
(words a+10, a+11) functions
as a forward torque limit value,
option command value 2
(words a+12, a+13) functions
as a reverse torque limit value
and the torque limit function is
enabled.
Torque com-
mand input
change
(Pn002.0)
Forward rota-
tion current limit
designation
(word a+16, bit
14
Reverse rota-
tion current limit
designation
(word a+16, bit
15)
R88D-WT
@
+ JUSP-NS115
R88D-WN
@
-ML2 with built-in
MECHATROLINK-II commu-
nications
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...
Страница 643: ...616 Revision History ...