24
Starting Operation
Section 2-2
The set values for Pn50B and Pn511 are written in the same way, i.e., by
changing the details of the Servo Parameters to be transferred and turning
ON the WRITE DATA Bit.
Writing the Pn50B Set Value
Writing the Pn511 Setting
The following diagram shows the operation used to transfer parameters to the
Servo Drive.
Word
Set value
Parameter transfer
setting
Details
CIO 117
050B hex
Servo Parameter No. Write Servo Parameter No.:
Pn50B
CIO 118
0002 hex
Parameter size
Write parameter size: 2 (bytes)
CIO 119
8883 hex
Write data (rightmost
word)
Write Servo Parameter setting:
8883
CIO 120
---
Write data (leftmost
word)
Parameter size is two bytes (one
word, so this is not used.) The set-
ting is ignored.
Word
Set value
Parameter transfer
setting
Details
CIO 117
0511 hex
Servo Parameter No. Write Servo Parameter No.: Pn511
CIO 118
0002 hex
Parameter size
Write parameter size: 2 (bytes)
CIO 119
6541 hex
Write data (rightmost
word)
Write Servo Parameter setting:
6541
CIO 120
---
Write data (leftmost
word)
Parameter size is two bytes (i.e.,
one word, so this is not used.) The
setting is ignored.
CIO 500
14
Servo Parameter Transferring Flag
This flag is ON while Servo parameters are being
saved, and turns OFF when saving is completed.
CIO 117
CIO 118
CIO 119
CIO 120
050A hex
0002 hex
2881 hex
CPU Unit
CIO 101
14
Pn50A
2881
Servo Drive (Axis 1)
CIO 500
14
---
Servo parameter No. (Pn50A)
Parameter length (2 bytes)
Set value (2881)
Axis Operating Input Memory Area
(Axis 1)
Axis Operating Output Memory Area
(Axis 1)
Servo Parameters Transferring Flag (ON while transferring)
PCU
MECHATROLINK
Non-volatile memory
Servo Parameters
saved.
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...
Страница 643: ...616 Revision History ...