![Omron CJ1W-MA - REV 10-2008 Скачать руководство пользователя страница 145](http://html1.mh-extra.com/html/omron/cj1w-ma-rev-10-2008/cj1w-ma-rev-10-2008_operation-manual_742343145.webp)
118
Servo Parameter Area
Section 4-5
Function Selection Parameters
Param-
eter No.
Parame-
ter name
Param-
eter
size
Contents
Default
setting
Unit
Setting
range
Enable
setting
Details
Digit
No.
Name
Set-
ting
Explanation
Pn000
Function
selection
basic
switch
2
0
Reverse rota-
tion
0
CCW direction is
taken for positive
command.
0
---
---
Offline
---
1
CW direction is
taken for positive
command.
1
Not used.
1
The setting is dis-
abled. (Do not
change the set-
ting.)
1
---
---
---
---
2
Unit No. setting 0 to F
Servo Drive com-
munications unit
number setting
when using per-
sonal computer
monitoring soft-
ware
0
---
---
Offline
---
3
Not used.
0
(Do not change the
setting.)
0
---
---
---
---
Pn001
Function
selection
applica-
tion switch
1
2
0
Select stop if
an alarm
occurs when
Servomotor is
OFF
0
Servomotor
stopped by
dynamic brake.
2
---
---
Offline
---
1
Servomotor
stopped by
dynamic brake.
Dynamic brake
released after stop-
ping.
2
Servomotor
stopped with free
run.
1
Select stop
when prohib-
ited drive is
input
0
Stop according to
Pn001.0 settings
(release Servomo-
tor after stopping).
0
---
---
Offline
---
1
Stop Servomotor
using torque set in
Pn406, and lock
Servomotor after
stopping.
2
Stop Servomotor
using torque set in
Pn406, and release
Servomotor after
stopping.
2
Select AC/DC
power input
0
AC power supply:
AC power supplied
from L1, L2, (L3)
terminals
0
---
---
Offline
---
1
DC power supply:
DC power supplied
from +1,
−
termi-
nals
3
Select warning
code output
0
Alarm code only
output from ALO1,
ALO2, ALO3
1
---
---
Offline
---
1
Alarm code and
warning code both
output from ALO1,
ALO2, ALO3
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...
Страница 643: ...616 Revision History ...