![Omron CJ1W-MA - REV 10-2008 Скачать руководство пользователя страница 567](http://html1.mh-extra.com/html/omron/cj1w-ma-rev-10-2008/cj1w-ma-rev-10-2008_operation-manual_742343567.webp)
540
List of Parameters
Appendix B
Speed Control Parameters
Pn216
Not used.
---
(Do not change the setting.)
0
---
---
---
---
Pn217
Not used.
---
(Do not change the setting.)
0
---
---
---
---
Pn281
Not used.
---
(Do not change the setting.)
20
---
---
---
---
Param-
eter No.
Parame-
ter name
Param-
eter
size
Contents
Default
setting
Unit
Setting
range
Enable
setting
Details
Digit
No.
Name
Set-
ting
Explanation
Pn300
Not used.
---
(Do not change the setting.)
600
---
---
---
---
Pn301
Not used.
---
(Do not change the setting.)
100
---
---
---
---
Pn302
Not used.
---
(Do not change the setting.)
200
---
---
---
---
Pn303
Not used.
---
(Do not change the setting.)
300
---
---
---
---
Pn304
Jog speed
2
Sets rotation speed during jog operation (using Servo
Drive’s personal computer monitoring software)
500
r/min
0 to
10000
Online
---
Pn305
Soft start
accelera-
tion time
2
Sets acceleration time during speed control soft start.
0
ms
0 to
10000
Online
---
Pn306
Soft start
decelera-
tion time
2
Sets deceleration time during speed control soft start. 0
ms
0 to
10000
Online
---
Pn307
Not used.
---
(Do not change the setting.)
40
---
---
---
---
Pn308
Speed
feedback
filter time
constant
2
Sets constant during filter of speed feedback.
0
×
0.01
ms
0 to
65535
Online
---
Pn310
Vibration
detection
switches
2
0
Vibration
detection
selection
0
Vibration detection
not used.
0
---
---
Online
---
1
Gives warning
(A.911) when vibra-
tion is detected.
2
Gives alarm
(A.520) when vibra-
tion is detected.
1
Not used.
---
(Do not change the
setting.)
0
---
---
---
---
2
Not used.
---
(Do not change the
setting.)
0
---
---
---
---
3
Not used.
---
(Do not change the
setting.)
0
---
---
---
---
Pn311
Vibration
detection
sensitivity
2
Sets the vibration detection sensitivity.
100
%
50 to
500
Online
---
Pn312
Vibration
detection
level
2
Sets the vibration detection level
50
r/min
0 to 500 Online
---
Param-
eter No.
Parame-
ter name
Param-
eter
size
Contents
Default
setting
Unit
Setting
range
Enable
setting
Details
Digit
No.
Name
Set-
ting
Explanation
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...
Страница 643: ...616 Revision History ...