431
Application Examples
Section 11-3
The Axis Operating Output/Input Memory Areas for axes 1 and 2 are based
on the settings of the Common Parameter Area, as shown below. The applica-
tion example in
11-3-1 Initial PCU Settings
shows a sample program that can
be used to make the following settings.
Beginning word of Axis Operating Output Memory Area: CIO 0000
(Axis 1 Operating Output Memory Area: CIO 0000 to CIO 0024)
(Axis 2 Operating Output Memory Area: CIO 0025 to CIO 0049)
Beginning word of Axis Operating Input Memory Area: CIO 1000
(Axis 1 Operating Input Memory Area: CIO 1000 to CIO 1024)
(Axis 2 Operating Input Memory Area: CIO 1025 to CIO 1049)
This sample program uses the following parts of the CPU Unit's I/O memory.
CPU Bus Unit Area
CIO 1500 to CIO 1524
These word addresses are contained in the CPU Bus Unit Area words allo-
cated to unit number 0.
Data Memory Area (DM Area)
Axis 1 Servo Parameter words: D10500 to D10503
Axis 2 Servo Parameter words: D10600 to D10603
These words are used to store the data required for a single Servo Parameter
transfer, including the Servo Parameter number, parameter size, and transfer
data (2 words).
EM Area bank 1
Servo Parameter list:
E1_00000 to E1_00257
Axis 1 Servo Parameter words: E1_01000 to E1_01511
Axis 2 Servo Parameter words: E1_02000 to E1_02511
Parameter list
Axis 1 Servo Parameter
Backup
E1_01000 to E1_01511
E1_00000 to E1_00257
Axis 2 Servo Parameter
Backup
E1_02000 to E1_02511
CPU Unit
PCU
Servo Parameters
Axis 1 Servo Drive
Servo Parameters
Axis 2 Servo Drive
Read together
Written/Saved together
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...
Страница 643: ...616 Revision History ...