170
Axis Operating Output Memory Areas
Section 4-7
4-7
Axis Operating Output Memory Areas
The Axis Operating Output Memory Areas contain outputs used to set opera-
tion for the Servo Drive and Servomotor axes that are connected using
MECHATROLINK communications. These outputs include operating com-
mands, such as direct operation, ORIGIN SEARCH, and JOG, and related
position and speed command values.
4-7-1
Axis Operating Output Memory Area Overview
The Axis Operating Output Memory Areas are allocated 25 words per axis in
the CPU Unit's memory area set in the PCU's Common Parameters (Axis
Operating Output Memory Area designation, beginning word of Axis Operat-
ing Output Memory Area).
The designated beginning word corresponds to the beginning word of the
area for axis 1, and the other areas are allocated words in sequence up to the
highest axis number registered in the scan list. For details on area allocations,
refer to
6-2-2 Scan List and PCU Area Allocations
.
The beginning words of the Axis Operating Output Memory Areas are deter-
mined by the axis number of each axis using the following equation.
Beginning Word of Axis Operating Output Memory Area for Axis N:
a= Beginning word of Axis Operating Output Memory Area specified in Com-
mon Para (N
−
1)
×
25 (N = 1 to 16)
Axis 1
No. 1
Axis 2
No. 2
Axis 3
No. 3
Axis 4
No. 4
Axis 14
No. 14
Axis 15
No. 15
Axis 16
No. 16
Word a+0
Word a+1
Word a+24
Word a+25
Word a+26
Word a+49
Word a+(N-1)
×
25
Word a+(N-1)
×
25+1
Word a+(N-1)
×
25+24
Word a+375
Word a+376
Word a+399
Axis
No.
MECHATROLINK
station address No.
:
:
Axis Operating Output Memory
Area Allocations
Axis 1
Operating
Output
Memory Area
Axis 2
Operating
Output
Memory Area
:
:
Axis N
Operating
Output
Memory Area
Axis 16
Operating
Output
Memory Area
:
:
:
:
a = Beginning word of Axis Operating Output Areas specified in Common Parameters
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...
Страница 643: ...616 Revision History ...