376
Torque Control
Section 10-6
Servo Parameter Area
G-series Torque Control Parameters
Pn05B is used to select the function of the option command value for torque
control.
The option command value for torque control is described in the following
pages.
Pn053 is used to set the fixed speed limit for torque control.
W-series Torque Control Parameters
Note
The default settings correspond to those used for W-series Servo Drives.
Pn002.1 is used to select the function of the option command value for torque
control. The option command value for torque control is described in the fol-
lowing pages.
The data length for Pn002.1 is the set value specified to transfer Pn002
(including Pn002.1) when transferring Servo Parameters. Pn407 is used to set
the fixed speed limit for torque control.
Axis Operating Output Memory Areas (Operating Commands)
Type
Parameter
No.
Parameter name
Unit
Setting
range
Data
length
Default
setting
---
Pn05B
Speed limit selection
---
0, 1
2
0
---
Pn053
Speed limit
r/min
−
20000 to
20000
2
50
Type
Parameter
No.
Parameter name
Unit
Setting
range
Data
length
Default
setting
---
Pn002.1
Function selection application switch 2
Speed command input switching
---
0, 1
2
0
---
Pn407
Speed limit
r/min
0 to 10000
2
3000
Name
Word
Bits
Contents
DECELERATION STOP
a
15
0
→
1: Starts deceleration stop.
TORQUE CONTROL
a+1
03
0
→
1: Starts torque control.
EMERGENCY STOP
15
0
→
1: Starts emergency stop.
Torque command value
a+8
a+9
---
Torque command value (rightmost word)
Torque command value (leftmost word)
Unit: 0.001%
(percentage of Servomotor’s momentary maximum torque)
Command range:
−
199.999 to 199.999%
(FFFCF2C1 hex to 00030D3F hex)
Note
The rotation direction is determined by the sign.
Option command value 1 a+10
a+11
---
Speed limit value (rightmost word)
Speed limit value (leftmost word)
Unit: 0.001%
(percentage of Servomotor's momentary maximum rotation speed)
Command range: 0 to 100.000% (See note 1.)
(00000000 hex to 000186A0 hex)
The option command value 1 can be used as the speed limit value during
torque control by setting the Servo Parameter
Speed Limit Selection
(Pn05B) when using G-series Servo Drives, and the
Speed Command Input
Change
in Servo Parameter
Function Selection Application Switch 1
(Pn002.1) when using W-series Servo Drives.
Forward rotation current
limit designation
a+16
14
1: Use forward torque limit.
Reverse rotation current
limit designation
15
1: Use reverse torque limit.
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...
Страница 643: ...616 Revision History ...