![Omron CJ1W-MA - REV 10-2008 Скачать руководство пользователя страница 528](http://html1.mh-extra.com/html/omron/cj1w-ma-rev-10-2008/cj1w-ma-rev-10-2008_operation-manual_742343528.webp)
501
List of Parameters
Appendix B
Pn00C
RS-232
Baud Rate
Setting
2
Sets the baud rate for RS-232 communications.
2
---
0 to 5
Online
0
2,400 bps
1
4,800 bps
2
9,600 bps
3
19,200 bps
4
38,400 bps
5
57,600 bps
Pn00D
Reserved
---
Do not change.
0
---
---
---
Pn00E
Reserved
---
Do not change.
0
---
---
---
Pn00F
Reserved
---
Do not change.
0
---
---
---
Pn010
Position
Loop Gain
(RT)
2
Sets the position loop responsiveness.
Increasing the gain increases position control responsiveness and
shortens stabilization time.
Oscillation or overshoot will occur if set too high. Adjust for opti-
mum responsiveness.
400
×
0.1
[1/s]
0 to 30000
Online
Settings
can be
changed
when the
axes are
stopped
(Busy
Flag for
each axis
= 0).
Pn011
Speed Loop
Gain (RT)
2
Sets the speed loop responsiveness.
If the Inertia Ratio (Pn020) is set correctly, this parameter is set to
the Servomotor response frequency.
Increasing the gain increases the speed control responsiveness,
but too much gain may cause oscillating.
Small gain may cause overshoot in the speed response.
Adjust for optimum responsiveness.
500
×
0.1
Hz
1 to 30000
Online
Pn012
Speed Loop
Integration
Time Con-
stant (RT)
2
Adjusts the speed loop integration time constant.
Set a large value for large load inertia.
Decrease the setting for fast response with small inertia.
Set 9999 to stop integration operation while retaining the integra-
tion value. A setting of 10000 disables integration.
200
×
0.1
ms
1 to 10000
Online
Pn013
Speed
Feedback
Filter Time
Constant
(RT)
2
Sets the type of speed detection filter time constant.
Normally, use a setting of 0.
Increasing the value reduces the noise of the Servomotor but also
reduces its responsiveness.
This parameter is disabled if the Instantaneous Speed Observer
Setting (Pn027) is enabled.
0
---
0 to 5
Online
Pn014
Torque
Command
Filter Time
Constant
(RT)
2
Adjusts the first-order lag filter time constant for the torque com-
mand section.
The torque filter setting may reduce machine vibration.
80
×
0.01
ms
0 to 2500
Online
Pn015
Speed
Feedfor-
ward
Amount
(RT)
2
Sets the speed feed-forward amount.
This parameter is particularly useful when fast response is
required.
300
×
0.1 % 0 to 1000
Online
Pn016
Feed-for-
ward Filter
Time Con-
stant (RT)
2
Sets the time constant for the speed feed-forward first-order lag fil-
ter.
100
×
0.01
ms
0 to 6400
Online
Pn017
Reserved
---
Do not change.
0
---
---
---
Param-
eter
No.
Parameter
name
Param-
eter
size
Setting
Explanation
Default
setting
Unit
Setting
range
Enable
setting
Details
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...
Страница 643: ...616 Revision History ...