![Omron CJ1W-MA - REV 10-2008 Скачать руководство пользователя страница 347](http://html1.mh-extra.com/html/omron/cj1w-ma-rev-10-2008/cj1w-ma-rev-10-2008_operation-manual_742343347.webp)
320
PCU Data Settings for Direct Operation
Section 9-3
G-series Servo Parameters
Servo Parameter Area
W-series and SMARTSTEP Junior Servo Parameters
Servo Parameter Area
First-step acceleration/deceleration curve operations require parameter set-
tings for Pn80B and Pn80E only. For the acceleration/deceleration curve,
Pn810 and Pn811 must be set when using an exponential curve, and Pn812
must be set when using an S-curve.
The SMARTSTEP Junior Servo Drives do not support the following parame-
ters: Pn80A, Pn80C, Pn80D, and Pn80F. They also do not support accelera-
tion/deceleration filters, so the filters cannot be set. One-step linear
acceleration/deceleration curves are set using only Pn80B and Pn80E.
For details on acceleration/deceleration curves, refer to
7-4 Acceleration and
Deceleration Operations
.
Type
Parame-
ter No.
Parameter name
Unit
Setting
range
Parame-
ter size
Default
setting
Accelera-
tion/decelera-
tion constants
Pn107
Linear acceleration constant
10,000 command
units/s
2
−
32768 to
32767
2
100
Pn10A
Linear deceleration constant
10,000 command
units/s
2
−
32768 to
32767
2
100
Accelera-
tion/decelera-
tion filters
Pn10E
Moving average time
0.1 ms
0 to 5100
2
0
Type
Parame-
ter No.
Parameter name
Unit
Setting
range
Parame-
ter size
Default
setting
W Series
SMART-
STEP
Junior
Accel-
eration/
decel-
eration
con-
stants
Pn80A
First-step linear accelera-
tion constant
10,000
command
units/s
2
1 to 65535
2
100
Sup-
ported
Not sup-
ported
Pn80B
Second-step linear acceler-
ation constant
10,000
command
units/s
2
1 to 65535
2
100
Sup-
ported
Sup-
ported
Pn80C
Acceleration constant
switching speed
100 com-
mand
units/s
0 to 65535
2
0
Sup-
ported
Not sup-
ported
Pn80D
First-step linear decelera-
tion constant
10,000
command
units/s
2
1 to 65535
2
100
Sup-
ported
Not sup-
ported
Pn80E
Second-step linear deceler-
ation constant
10,000
command
units/s
2
1 to 65535
2
100
Sup-
ported
Sup-
ported
Pn80F
Deceleration constant
switching speed
100 com-
mand
units/s
0 to 65535
2
0
Sup-
ported
Not sup-
ported
Accel-
eration/
decel-
eration
filters
Pn810
Exponential accelera-
tion/deceleration bias
Command
units/s
0 to 32767
2
0
Sup-
ported
Not sup-
ported
Pn811
Exponential accelera-
tion/deceleration time con-
stant
0.1 ms
0 to 5100
2
0
Sup-
ported
Not sup-
ported
Pn812
Movement average time
0.1 ms
0 to 5100
2
0
Sup-
ported
Not sup-
ported
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...
Страница 643: ...616 Revision History ...