![Omron CJ1W-MA - REV 10-2008 Скачать руководство пользователя страница 222](http://html1.mh-extra.com/html/omron/cj1w-ma-rev-10-2008/cj1w-ma-rev-10-2008_operation-manual_742343222.webp)
195
Axis Operating Input Memory Areas
Section 4-8
Torque Limit Status Flag
Word
b+1
Bit
09
Function
This flag turns ON when the Servomotor's output torque is limited by the
torque limit.
For W-series Servo Drives, the torque limit will be the lowest among all the
limit values that are enabled for the torque limits specified in
Forward Torque
Limit
(Pn402),
Reverse Torque Limit
(Pn403),
Forward Rotation External Cur-
rent Limit
(Pn404),
Reverse Rotation External Current Limit
(Pn405), or in the
option command value for speed control.
For G-series Servo Drives, the torque limit will be the lowest among all the
limit values that are enabled for the torque limits specified in
No.1 Torque Limit
(Pn05E),
No.2 Torque Limit
(Pn05F), or in the option command value for
speed control.
0: Torque limit function disabled
1: Torque limit function enabled
Details
Refer to
10-4 Torque Limits
.
Positioning Proximity Flag (during Position Control)
Speed Limit Status Flag (during Torque Control)
Word
b+1
Bit
11
Function
The function of these flags depends on whether position control or torque
control is being used.
During Position Control: Positioning Proximity Flag
This flag turns ON when the feedback position is within the range for Servo
Parameter
Positioning Completion Range 2
(Pn504 for R88D-WT
@
and
Pn524 for R88D-WN
@
-ML2 and SMARTSTEP Junior) for the target (stop)
position.
0: Outside
Positioning Completion Range 2
1: Within
Positioning Completion Range 2
During Torque Control: Speed Limit Status Flag
This flag turns ON when the feedback speed during torque control is limit-
ed by the Servo Parameter
Speed Limit
(Pn407), or option command val-
ue.
0: Speed limit function disabled
1: Speed limit function enabled
Details
Refer to
10-6-2 Starting Torque Control
.
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...