285
Origin Search Operation
Section 8-2
a = Beginning word of Axis Operating Output Areas specified in Common
Para (Axis No.
−
1)
×
25
The speed command value specifies the initial origin search speed until the
origin proximity signal is input. When an origin search is started with the
speed command set to 0 (command units/s), a Speed Designation Error (axis
error code: 3061) will occur and the origin search will not be executed.
Torque limit during operation is possible with origin searches. For further
details on the torque limit function, refer to
10-4 Torque Limits
.
The speed command value, acceleration/deceleration curve designation, and
forward/reverse rotation current limit designation data are enabled when the
ORIGIN SEARCH Bit turns ON.
The SMARTSTEP Junior Servo Drives do not support acceleration/decelera-
tion filters and torque limits. When using a SMARTSTEP Junior Servo Drive,
do not attempt to use an acceleration/deceleration curve designation or for-
ward/reverse torque limit designation.
Note
Do not set both the exponential curve designation and S-curve designation to
1 (enabled) in the acceleration/deceleration curve designation. Enabling both
settings may cause a malfunction.
Axis Operating Input Memory Areas (Monitor)
b = Beginning word of Axis Operating Input Areas specified in Common
Para (Axis No.
−
1)
×
25
Accelera-
tion/
decelera-
tion curve
designa-
tion
Exponential
curve desig-
nation
a+16
03
1: Use exponential acceleration/
deceleration curve.
Not sup-
ported
Supported
Not sup-
ported
S-curve des-
ignation
04
1: Use S-curve acceleration/
deceleration curve.
Supported
Supported
Not sup-
ported
Forward rotation current
limit
14
1: Use forward torque limit
Supported
Supported
Not sup-
ported
Reverse rotation current
limit
15
1: Use reverse torque limit
Supported
Supported
Not sup-
ported
Name
Word
Bits
Contents
G Series
W Series
SMARTSTE
P Junior
Name
Word
Bits
Contents
PCU Positioning Com-
pleted Flag
b
05
0
→
1: Positioning completed.
No Origin Flag
06
0: Origin established.
1: No origin established.
Origin Stop Flag
07
0: Outside origin range.
1: Within origin range.
Error Flag
12
0: No axis error.
1: Axis error.
Busy Flag
13
1: Axis busy (axis operation executing)
Feedback present posi-
tion
b+6
b+7
---
Present position:
Feedback position (rightmost word)
Feedback position (leftmost word)
Command present posi-
tion
b+8
b+9
---
Present position:
Command position (rightmost word)
Command position (leftmost word)
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...
Страница 643: ...616 Revision History ...