Overview
When performing positioning for a system in terms of absolute positions in
that system, it is first necessary to define the origin. For example, in the X-Y
plane shown below, before positioning to (X, Y) = (100 mm, 200 mm), the ori-
gin (0,0) of the machine must be established, i.e., it is necessary to define the
origin.
With the PCU, the mechanical origin can be defined using any of the following
three methods.
The PCU also features a positioning function to return to the established ori-
gin.
The PCU can also be operated without defining the origin but the axis opera-
tion for each function is as follows:
Name
Contents
ORIGIN SEARCH
The origin is determined by actually operating the Servomotor
and using the limit input signal, origin proximity input signal,
and origin input signal.
A photoelectric sensor or the phase Z signal from an encoder
can be used as the origin input signal.
Execute this function when using an incremental encoder Ser-
vomotor or Servomotor with absolute encoder used as an
incremental encoder.
PRESENT POSI-
TION PRESET
The origin can be determined by forcibly setting the position at
which the Servomotor is stopped to a user-specified position.
ABSOLUTE
ENCODER ORIGIN
By using a Servomotor with absolute encoder, the absolute
value data saved in the encoder can be read and the mechan-
ical origin can be established when starting to use the device.
Name
Contents
ORIGIN RETURN
Positioning is performed from the position where the Servo-
motor is stopped to the origin that has been established using
ORIGIN SEARCH or PRESENT POSITION PRESET.
Function
Operation
JOG
Can be executed.
ORIGIN RETURN
Cannot be executed.
If executed, a Present Position Unknown Error
(axis error code: 3030 hex) will occur.
Y axis
X axis
•
(100, 200)
(0, 0)
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...
Страница 643: ...616 Revision History ...