![Omron CJ1W-MA - REV 10-2008 Скачать руководство пользователя страница 128](http://html1.mh-extra.com/html/omron/cj1w-ma-rev-10-2008/cj1w-ma-rev-10-2008_operation-manual_742343128.webp)
101
Servo Parameter Area
Section 4-5
The timing for Servo Parameters to be enabled are classified into the following
two types.
Online (online parameters): Changed settings are enabled immediately after
Servo Parameters have been written.
Offline (offline parameters): Changed settings are enabled when the Servo
Drive power is cycled or DEVICE SETUP is exe-
cuted.
The
Details
column indicates whether the following conditions apply to the
corresponding parameter.
• Online parameters that can be changed when the axis is stopped (Busy
Flag = 0) only.
• Parameters with standard set values when using MECHATROLINK are
indicated in the
Details
column as “standard” with the set value.
The standard settings are basic settings required when using the PCU.
This manual describes operations assuming standard settings are being
used.
For details on fixed and standard settings, refer to
6-4 Standard Settings for
Servo Drives Using MECHATROLINK
.
Note
Parameters marked with "(RT)" are automatically set during realtime autotun-
ing. To set these parameters manually, disable realtime autotuning by setting
the Realtime Autotuning Mode Selection (Pn021) to 0 before changing the
parameter.
Note
Make sure that the equipment will not be adversely affected before changing
the Servo Parameters (WRITE SERVO PARAMETER, SAVE SERVO
PARAMETER). Refer to the
Servo Drive's operation manual
and always check
the effect of changing the settings before changing the Servo Parameters.
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...
Страница 643: ...616 Revision History ...