![Omron CJ1W-MA - REV 10-2008 Скачать руководство пользователя страница 204](http://html1.mh-extra.com/html/omron/cj1w-ma-rev-10-2008/cj1w-ma-rev-10-2008_operation-manual_742343204.webp)
177
Axis Operating Output Memory Areas
Section 4-7
❍
: Execution possible
×
: A multistart error (axis error code: 3050) will occur and the function will not
be executed.
---: Execution not possible (ignored)
Note:
The above table assumes that the conditions required for executing jog-
ging, origin searches, origin returns, absolute/relative movements
(including interrupt feeding), speed control, or torque control, such as
command values and origin establishment, have been met.
Executing Multiple Functions Simultaneously
The following table shows the PCU operations when multiple functions are
executed at the same time for the same axis during a servo lock (including
executing other functions while the Receiving Command Flag is ON.
DECELERATION STOP
❍
❍
❍
---
---
---
---
---
---
---
---
---
---
---
---
JOG
❍
❍
❍
❍
---
×
×
×
×
×
×
×
×
×
---
ORIGIN SEARCH
❍
❍
❍
❍
×
×
×
×
×
×
×
×
×
×
---
ORIGIN RETURN
❍
❍
❍
❍
×
×
×
×
×
×
×
×
×
×
---
POSITION CONTROL (ABSO-
LUTE MOVEMENT)
❍
❍
❍
❍
×
×
×
❍
❍
×
❍
❍
×
×
---
POSITION CONTROL (RELA-
TIVE MOVEMENT)
❍
❍
❍
❍
×
×
×
❍
❍
×
❍
❍
×
×
---
INTERRUPT FEEDING
❍
❍
❍
❍
×
×
×
×
×
×
❍
❍
×
×
---
SPEED CONTROL
❍
---
❍
❍
×
×
×
❍
❍
❍
❍
❍
×
×
---
TORQUE CONTROL
❍
---
❍
❍
×
×
×
❍
❍
❍
❍
❍
×
×
---
PRESENT POSITION PRESET
❍
×
❍
❍
×
×
×
×
×
×
×
×
×
×
×
DEVICE SETUP
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
SERVO LOCK
❍
---
---
---
×
×
×
×
×
×
×
×
×
×
×
Function to be executed (See note.)
Executing function
SER
V
O
UNLOCK
DEVIA
T
ION CO
UNTER
RESET
EM
ERGENCY ST
OP
DEC
E
LERA
T
ION
ST
OP
JO
G
O
R
IG
IN SE
A
RCH
O
R
IG
IN RET
U
R
N
AB
SOLUT
E
M
O
VEM
ENT
RELA
T
IVE M
O
VEM
ENT
INTERR
UPT
FEEDING
SPEED CON
T
R
O
L
T
O
R
Q
UE CONTR
O
L
PRESENT POSITION PRESET
DEVICE SETUP
SER
V
O
LOCK
Function
Operation for simultaneous execution
SERVO UNLOCK
Takes priority over any other function executed at the
same time.
All other operations are disabled while the SERVO
UNLOCK Bit is ON.
DEVIATION COUNTER
RESET
Takes priority over any other function executed at the
same time except for SERVO UNLOCK.
The following functions will not be started while the DEVI-
ATION COUNTER RESET Bit is ON.
EMERGENCY STOP
Executed before any other function executed at the same
time, except SERVO UNLOCK or DEVIATION COUNTER
RESET.
All other operation functions are disabled while the
EMERGENCY STOP Bit is ON.
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...
Страница 643: ...616 Revision History ...