179
Axis Operating Input Memory Areas
Section 4-8
4-8
Axis Operating Input Memory Areas
The Axis Operating Input Memory Areas are allocated inputs for monitoring
the status of axis operations of the Servo Drive and Servomotor axes that are
connected using MECHATROLINK communications. These include present
position and axis operating status.
4-8-1
Axis Operating Input Memory Area Overview
The Axis Operating Input Memory Areas are allocated 25 words for each axis
in the CPU Unit's memory area set in PCU's Common Parameters (Axis
Operating Input Memory Area designation and beginning word of Axis Oper-
ating Input Memory Area).
The designated beginning word corresponds to the beginning word of the
area for axis 1, and the other areas are allocated words in sequence up to the
highest axis number registered in the scan list. For details on area allocations,
refer to
6-2-2 Scan List and PCU Area Allocations
.
The beginning words of the Axis Operating Input Memory Areas are deter-
mined by the axis number of each axis using the following equation.
Beginning Word of Axis Operating Input Memory Area for Axis N:
b = Beginning word of Axis Operating Input Memory Area specified in Com-
mon Para (N
−
1)
×
25 (N = 1 to 16)
Axis 1
No. 1
Axis 2
No. 2
Axis 3
No. 3
Axis 4
No. 4
Axis 14
No. 14
Axis 15
No. 15
Axis 16
No. 16
Word b+0
Word b+1
Word b+24
Word b+25
Word b+26
Word b+49
Word b+(N-1)
×
25
Word b+(N-1)
×
25+1
Word b+(N-1)
×
25+24
Word b+375
Word b+376
Word b+399
Axis
No.
MECHATROLINK
station address No.
:
:
Axis Operating Input Memory
Area Allocations
Axis 1
Operating
Input Memory
Area
Axis N
Operating
Input Memory
Area
Axis 16
Operating
Input Memory
Area
Axis 2
Operating
Input Memory
Area
:
:
:
:
b: Beginning word of the Axis Operating Memory Areas specified in the Common Parameters.
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...
Страница 643: ...616 Revision History ...