![Omron CJ1W-MA - REV 10-2008 Скачать руководство пользователя страница 605](http://html1.mh-extra.com/html/omron/cj1w-ma-rev-10-2008/cj1w-ma-rev-10-2008_operation-manual_742343605.webp)
578
List of Error Codes
Appendix D
Note
(1) Errors that occur in the MECHATROLINK-II Application Module cannot be detected by the PCU be-
cause the communications connection is not established. The PCU is not able to detect the corre-
sponding axis during execution of CONNECT, so an MLK Initialization Error (Unit error code: 0020
hex) will occur.
(2) This alarm occurs when using an R88D-WT
@
W-series Servo Drive together with the JUSP-NS115
MECHATROLINK-II Application Module.
(3) This alarm occurs when using an R88D-WN
@
-ML2 W-series Servo Drive.
(4) This alarm may occur when a SMARTSTEP Junior Servo Drive (R7D-ZN
@
-ML2) is being used. The
A.28 (emergency stop) alarm is treated as an emergency stop signal input error (axis error code:
3004 (hex) in the Position Control Unit and the Servo will be unlocked for the axis.
(5) This alarm is not detected for SMARTSTEP Junior Servo Drives (R7D-ZN
@
-ML2).
List of W-series and SMARTSTEP Junior Warning Displays
Note
(1) This warning is not detected for SMARTSTEP Junior Servo Drives (R7D-ZN
@
-ML2).
(2) If a Parameter Setting Warning or MECHATROLINK-II Command Warning occurs in the Servo
Drive, a data setting error (axis error code: 3099 hex) will occur at the PCU, and the active axis in
which the error occurred will decelerate to a stop.
(3) If a MECHATROLINK-II communications error occurs once independently, a communications warn-
ing occurs, and the PCU will perform a communications retry. If the communications warning occurs
continually, a communications error will occur.
A.F5 (See
note 2.)
40F5
Motor current error
The current to the Servomotor is too small for the torque com-
mand from the Servo Drive.
A.F6 (See
note 2.)
40F6
Motor conduction error
The Servo is ON, but the Servomotor is not conducting current
regardless of the Servo Drive settings and external input.
Servo Drive
display
PCU error
code
Error detection function
Detected error or cause of error
Servo Drive
display
PCU error
code
Warning detection
function
Warning details
A.90
@
(See
note 1.)
4090
Deviation counter over-
flow
The number of pulses in the deviation counter has exceeded the
deviation counter overflow level set in Pn505 (when using R88D-
WT
@
) or Pn520 (when using R88D-WN
@
-ML2) multiplied by the
rate (%) set in Pn51E.
A.91
@
4091
Overload or fluctuation
This warning occurs before the Overload Alarm (A.71
@
, A.72
@
)
occurs. If operation is continued in this state, an alarm may
occur. This warning also occurs when an abnormal fluctuation is
detected in the Servomotor rotation speed.
A.92
@
(See
note 1.)
4092
Regeneration overload
This warning occurs before the Regeneration Overload Alarm
(A.32) occurs. If operation is continued in this state, an alarm
may occur.
A.93
@
(See
note 1.)
4093
Battery warning
(Absolute encoders only)
This warning occurs before the Battery Error (A.83) occurs. If the
power is turned OFF, an alarm may occur the next time the
power is turned ON. (Replace the battery while the control circuit
power supply is ON.)
A.94
@
See note 2. Parameter setting warn-
ing
A value outside the setting range has been set for the MECHA-
TROLINK slave station device.
A.95
@
See note 2. MECHATROLINK-II com-
mand warning
An illegal communications command or unsupported communi-
cations command has been sent to the MECHATROLINK slave
station device.
A.96
@
4096
Communications warning A single MECHATROLINK-II communications error has
occurred. (See note 3.)
Содержание CJ1W-MA - REV 10-2008
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 21: ...xxii ...
Страница 57: ...30 Starting Operation Section 2 2 ...
Страница 97: ...70 Wiring Section 3 4 ...
Страница 247: ...220 Transferring Servo Parameters Section 5 3 ...
Страница 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Страница 343: ...316 Absolute Encoder Origin Section 8 6 ...
Страница 375: ...348 Linear Interpolation Section 9 7 ...
Страница 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Страница 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Страница 641: ...614 Index ...