Speed existence –
DNZS
(Function code data = 70)
This output signal comes ON when the detected speed is equal to or higher than the stop speed. It is
not affected by any run command to the inverter.
■
Speed agreement –
DSAG
(Function code data = 71)
This output signal comes ON when the difference between reference speed (final) and detected speed
is within the range specified by H74 and it goes OFF when the difference is out of the allowable
band for the time longer than the one specified by H75. It is not affected by any run command to the
inverter.
For details, refer to the description of function codes H74 and H75 (Speed Agreement).
■
Speed arrival 3 –
FAR3
(Function code data = 72)
This output signal comes ON when the difference between the detected speed and reference speed
(pre-ramp) comes within the allowable error zone (specified by E30).
It is not affected by any run command to the inverter.
For details, refer to the description of function code E30 (Speed Arrival).
■
During acceleration and During deceleration –
DACC
and
DDEC
(Function code data = 73 and 74)
The output signal
DACC
or
DDEC
come ON depending on whether the motor is accelerating or
decelerating by comparing the reference speed (pre-ramp) with the detected speed. These output
signals are not affected by any run command to the inverter.
For details, refer to the description of function code E30 (Speed Arrival).
■
During zero speed –
DZR
(Function code data = 75)
This output signal comes ON when the main circuit (output gate) of the inverter is ON and the
detected speed is lower than the stop speed specified by function code F25.
■
PG abnormal –
PG-ABN
(Function code data = 76)
This output signal comes ON when any PG error is detected.
For details, refer to the description of function codes L90 to L92 (PG Error Detection).
■
Door control –
DOPEN
(Function code data = 78)
This output signal controls the elevator door.
For details, refer to the description of function codes L87 to L89 (Door Control) and L99
(bit6).
■
Alarm output (for any alarm) –
ALM
(Function code data = 99)
■
EN detection circuit fault –
DECF
(Function code data = 101)
This output signal comes ON when the [EN
1]/[EN2]
status detection circuit is defective. It can be
outputted separately from the relay alarm output.
■
EN terminal off –
ENOFF
(Function code data = 102)
2-64
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...