2.3 Overview of Function Code
C
hap.
2
FUN
CT
IO
N
C
O
D
E
S
E10 to E17
Acceleration/Deceleration Time 3 to 10
F07 and F08
(Acceleration/Deceleration Time 1 and 2)
E10 to E17 specify the acceleration or deceleration time in linear acceleration/deceleration zones
excluding S-curve zones.
For details, refer to the descriptions of function codes F07 to F08 (Acceleration/Deceleration
Time 1, 2).
E18
Run Command/Multistep Speed Command Agreement Timer (Mode)
E19
Run Command/Multistep Speed Command Agreement Timer (Time)
E18 and E19 set the run command/multistep speed command agreement timer to avoid signals
chattering problems.
■
Mode (E18)
E18 specifies applicable commands for the agreement timer.
Data for E18
Applicable commands
FWD
,
REV
SS1
,
SS2
,
SS4, SS8
0
--
--
1
√
--
2
--
√
3
√
√
■
Time (E19)
E19 specifies the period to confirm whether the terminal command
FWD
/
REV
or
SS1
/
SS2
/
SS4/SS8
is kept ON or OFF after the command is switched ON or OFF. If the command is kept ON during
time specified in E19, the inverter recognizes the command being ON.
- Data setting range: 0.000 to 0.100 (s)
Application of the agreement timer
- Confirmation for run command
Run command
ON
ON
Period specified by E19
Run command OFF
Run command ON
Less than the period
specified by E19
- Confirmation for multistep speed command
Less than the period
specified by E19
SS1
SS2
ON
ON
Period specified by E19
Low speed
High speed
SS4
ON
ON
2-57
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...