E61
Analog Input for [12] (Extension function selection)
C31 (Analog Input Adjustment for [12], Offset)
C32 (Analog Input Adjustment for [12], Gain)
C33 (Analog Input Adjustment for [12], Filter time constant)
E62
Analog Input for [V2] (C1 function) (Extension function selection)
C36 (Analog Input Adjustment for [V2], Offset)
C37 (Analog Input Adjustment for [V2], Gain)
C38 (Analog Input Adjustment for [V2], Filter time constant)
E63
Analog Input for [V2] (V2 function) (Extension function selection)
C41 (Analog Input Adjustment for [V2], Offset)
C42 (Analog Input Adjustment for [V2], Gain)
C43 (Analog Input Adjustment for [V2], Filter time constant)
E61, E62, and E63 define the functions of terminals [12], [V2] (V2 function), and [V2] (C1 function),
respectively.
Terminals [12] and [V2] (V2 function) are voltage input terminals, and terminal [V2] (C1 function)
is a current input terminal.
Data for E61,
E62, or E63
Input assigned to
[12] and [V2]
Description
0
None
--
1
Speed command
(Operation is not
reversible with the
polarity)
Input an analog speed command to terminal [12] or [V2]
(V2 function) by 0 to 10 VDC, and [V2] (C1 function)
by 4 to 20 mADC for 0 to 100% of the maximum speed.
2
Speed command
(Operation is reversible
with the polarity)
Input an analog speed command to terminal [12] or [V2]
(V2 function) by -10 to 10 VDC for -100 to 100% of the
maximum speed.
Do not assign this data for the terminal [V2] (C1
function).
4
Torque bias
command
Input an analog torque bias to terminal [12] or [V2] (V2
function) by -10 to 10 VDC for -100 to 100% of the
rated torque in analog command value.
Input an analog torque bias to terminal [V2] (C1
function) by 4 to 20 mADC for 0 to 100% of the rated
torque in analog command value.
When C22 is 0
Set 1 or 2 to E61 (E62, E63) when you want to use the analog multistep speed command.
When C22 is 1
Set 1 or 2 to E63 when you want to use the analog multistep speed command.
Do not set 1 or 2 to E61 and E62.
Refer to the descriptions of function codes F01, L54 for analog speed commands, analog
torque bias, respectively. Offset, gain, and filter time constant can be specified for individual
terminals by function codes C31 to C33, C36 to C38 and C41 to C43.
If these terminals have been set up by function codes to have the same data, the specified
values will be added up.
2-74
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...