2.3 Overview of Function Code
C
hap.
2
FUN
CT
IO
N
C
O
D
E
S
P09
Motor (Slip comp. driving gain)
P10
Motor (Slip comp. braking gain)
P09 and P10 specify the slip compensation gain in percentage to the rated slip (P12) at the driving
and braking sides, respectively.
- Data setting range: (P09, P10): 0.0 to 200.0 (%)
P11
Motor (Slip comp. response time)
Determines the response time for slip compensation. Basically, there is no need to modify the default
setting.
- Data setting range: 0.05 to 1.00 (s)
It is a special code of the torque vector control.
Refer to page 2-2 for the control mode of the inverter.
P12
Motor (Rated slip)
P12 specifies the rated slip frequency of the motor.
- Data setting range: 0.00 to 15.00 (Hz)
The rated slip frequency is calculated with the following formula.
r/min)
(
speed
s
Synchronou
(r/min)
speed
Rated
-
r/min)
(
speed
s
Synchronou
(Hz)
frequency
Rated
(Hz)
frequency
slip
Rated
×
=
When the P12 is set to 0.00, the applied value corresponds to Fuji standard motor’s rated slip
frequency.
Motor capacity (P02)
Value applied when P12=0.00
2.2kW
1.93 Hz
3.7kW
1.57 Hz
5.5kW
1.18 Hz
7.5kW
1.28 Hz
11kW
0.95 Hz
15kW
0.90 Hz
18.5kW
0.72 Hz
22kW
0.72 Hz
30kW
0.91 Hz
37kW
0.64 Hz
45kW
0.72 Hz
P60, P62
and P63
Motor (Armature resistance – Rs)
(Armature q-axis reactance – Xs)
(Interphase inductive voltage - E)
P60, P62 and P63 specify the armature resistance, q-axis inductance, and interphase inductive voltage of
the motor, respectively.
These functions are used with L130 to L133.
2-87
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...